> Does anyone know why 30 is the wire junction connection limit?
> Wouldn't it have more to do with whether the segment centers of adjoining
wires
> intersec trather than with an arbitrary number.
For as far as I know, the second applies and is the number limited to 30
because in most models when using more than 30 wires (in a single plane)
these wires would too much intersect each other.
However note that this limit applies to all wires connected to a single
segment. If you would connect 16 or more wires to each side of a segment
the limit is also violated.
That's why in the Nec2DXS.exe executables, I increased this limit to 60...
Arie.
-- (Please ignore the advertisements below) +++ GMX - die erste Adresse für Mail, Message, More +++ Neu: Preissenkung für MMS und FreeMMS! http://www.gmx.net -- The NEC-List mailing list <nec-list_at_gweep.ca> http://www.gweep.ca/mailman/listinfo.cgi/nec-listReceived on Mon Jan 12 2004 - 13:50:30 EST