NEC-LIST: LD 0 command in NEC4.

From: D. B. Miron <dbmiron_at_email.domain.hidden>
Date: Fri, 2 Jan 2004 13:56:04 -0800 (PST)

Good day,

The following list runs in NEC2 but not in NEC4. It will
run in NEC4 if I take out the LD 0... line. It seems okay
by the manual. What am I missing?

Thanks,

Doug Miron

CM 4 MHz monopole driven against 8 10 m radials.

CE

GW 1 3 0 0 0.1 0 0 0.4 0.0127

GW 2 5 0 0 0.4 0 0 18.75 0.0127

GW 3 5 0 0 0.025 10 0 2.5 0.0008

GW 4 5 0 0 0.025 7 7 2.5 0.0008

GW 5 5 0 0 0.025 0 10 2.5 0.0008

GW 6 5 0 0 0.025 -7 7 2.5 0.0008

GW 7 5 0 0 0.025 -10 0 2.5 0.0008

GW 8 5 0 0 0.025 -7 -7 2.5 0.0008

GW 9 5 0 0 0.025 0 -10 2.5 0.0008

GW 10 5 0 0 0.025 7 -7 2.5 0.0008

GW 11 1 0 0 0.1 0 0 0.025 0.0127

GE -1

GN 2 0 0 0 13 0.005

EX 0 1 2 1 316 0 1

LD 0 2 1 1 0 5E-6 0

LD 5 0 0 0 5.8E+07 1

FR 0 2 0 0 3.5 0.5

PT -1

RP 0 6 1 1000 60 0 5 0

EN

-- 
The NEC-List mailing list <nec-list_at_gweep.ca>
http://www.gweep.ca/mailman/listinfo.cgi/nec-list
Received on Fri Jan 02 2004 - 21:56:21 EST

This archive was generated by hypermail 2.2.0 : Sat Oct 02 2010 - 00:10:44 EDT