Hello Jeff,
this might do better:
CM Discone
CE
GW 1 1 0 0 0.462 0 0 0.452 0.001 ' EX wire
GW 2 3 0 0 0.462 0.17 0 0.462 .001 ' Top hat wire
GW 3 14 0.019 0 0.452 0.126 0 0.211 0.005 ' Sloping wire
GM 2 7 0 0 45 0 0 0 2 ' Full discone
GM 100 1 0 0 0 0.5 0 0 1 ' second
GM 100 1 0 0 0 -0.5 0.5 0 101 ' third
GM 100 1 0 0 0 0 -1.25 0 201 ' fourth
GM 100 1 0 0 0 -0.75 0.75 0 301 ' fifth
GS 0 0 0.42827494
GE
EX 0 1 1 0 1 0
EX 0 101 1 0 1 0
EX 0 201 1 0 1 0
EX 0 301 1 0 1 0
EX 0 401 1 0 1 0
GN 2 0 0 0 13 5.e-3
FR 0 1 0 0 700 0
EK
EN
You could take a further look at the tag-increment and from tag
description for the GM card as included in the Nec2 user-manual.
It's not a 4nec2 problem, but a Nec2 problem as you will see when viewing
the nec2 output-file (F8 key).
When using a number of GM cards its mostly wise to add them one at a time
and see what results you get in intermediate stages.
Furthermore the GE card was missing and there are some other geometry
errors, such as an one open end for the wire on which the EX is
positioned, and too large a radius change for this wire to the other
connected wire(s).
Hope this is somewhat of help.
success,
Arie.
-- (Please ignore the advertisements below) Psssst! Schon vom neuen GMX MultiMessenger gehört? Der kann`s mit allen: http://www.gmx.net/de/go/multimessenger -- The NEC-List mailing list NEC-List_at_robomod.net http://www.robomod.net/mailman/listinfo/nec-listReceived on Tue Jan 29 2008 - 10:40:10 EST