Hello Richard,
> I want to drive a transmission line with a voltage source, but
> put a load in series with the source. If I construct a short
> floating segment and put the source and transmission line on
> it, I can drive the transmission line directly from the source
> with no series load.
You can place the load, the voltage source and the transmission-
line on the same segment. When placed on the same segment, loads
are 'connected' in series with the voltage source, transmission-
lines are 'connected' in parallel with it.
Arie.
-- (Please ignore the advertisements below) Der GMX SmartSurfer hilft bis zu 70% Ihrer Onlinekosten zu sparen! Ideal für Modem und ISDN: http://www.gmx.net/de/go/smartsurfer -- The NEC-List mailing list NEC-List_at_robomod.net http://www.robomod.net/mailman/listinfo/nec-listReceived on Thu Nov 16 2006 - 08:23:02 EST