Ken (and others),
> Thanks! Works nice now. Downloaded all the compiled runtimes and placed
> them into the exe directory. Worked out real nice, it automatically used
> the 3000 segment exe. (one problem that keep popping up is "wire @ zero
> height not 'connected' to ground (screen)". I can't seem to find this? I
> have a 'wall' that connects to ground, and 3 legs of a table which
> connects also to a wall. Legs go to '0' Z.??
You could send me your *.nec file, so I could take a look at it...
> Now one more question. I want to run a 'sweep' from say 2MHz to 100MHz
> in a log type step. Say 2,6,10,30,60,100. How do I setup an automatic
> run of frequencies and also use a GUI visualizer to run through each
> frequency? Or do I have to do each manually?
Hmmm, I did not (yet) include the possibility to automatically run
logarithmic sweeps. You could try inserting the required FR card manually in
your *.nec file and run with 'use original file', to see what results you
get.
However keep in mind that at 2 and 100 Mhz segmentation requirements are
much different. This might cause you some problems.
Greetings,
Arie Voors.
-- (Please ignore the advertisements below) +++ GMX - die erste Adresse für Mail, Message, More +++ 10 GB Mailbox, 100 FreeSMS http://www.gmx.net/de/go/topmail -- The NEC-List mailing list NEC-List_at_robomod.net http://www.robomod.net/mailman/listinfo/nec-listReceived on Tue Apr 26 2005 - 11:49:19 EDT