NEC-LIST: Coil Q

From: Greg Durnan <gdurnan_at_email.domain.hidden>
Date: Tue, 08 Feb 2005 09:23:11 -0600

Hello,

I've been building radio coils for the last year for nmr instruments.
I construct them for use between say 40 and 400MHz and use copper or
silver plated wire ( generally about 40 to 400nH - perhaps 1 to 10
turns on up to a 10mm air core). Q's generally range between 50 and
200 ( a particularly good one) when coils are used in conjunction with
good ATC ceramic caps. I have seen slightly higher Q's perhaps ( maybe
mid 350's) on occasion, but I would be reluctant to offer any
guarantees on those types of numbers. Testing has generally been done
on a by using the curve fit on a VNA notch measurement... perhaps not
the best way.

G.J.Durnan

-- 
No virus found in this outgoing message.
Checked by AVG Anti-Virus.
Version: 7.0.300 / Virus Database: 265.8.5 - Release Date: 3/02/2005
-- 
The NEC-List mailing list
NEC-List_at_robomod.net
http://www.robomod.net/mailman/listinfo/nec-list
Received on Tue Feb 08 2005 - 15:24:35 EST

This archive was generated by hypermail 2.2.0 : Sat Oct 02 2010 - 00:10:45 EDT