Re: NEC-LIST:Imperfect Ground

From: Rob <rob_at_email.domain.hidden>
Date: Wed, 27 Nov 2002 06:38:37 -0800

Hi Roy and Dr. Hui,

I took some of my ground permitivity and conductance values right out of
Eznec for my ASAP port to Python. The idea was to be able to compare
Eznec and ASAP. However, realize that ASAP does not yet have the
Summerfeld half-space ground condition added. ....YET!!

If you go to my website, download ASAP.TGZ, you can find a whole bunch
of ground parameters near the beginning of the file for the "GROUND"
card. (we say card because it used to be FORTRAN :)

Sincerely, Rob.

Roy Lewallen wrote:
>
> A conductivity of 5 mS/m and dielectric constant of 13 are often used as
> being representative of "average" or "typical" ground.
>
> Roy Lewallen
>
> Lee Yee Hui (Dr) wrote:
> > Hi everybody,
> >
> > Good day! Could I find out if anybody has an idea of a
> > typical ground conductivity and typical ground dielectric constant
> > value that I can use to model imperfect ground conditions?
> >
> > Thank you in advance and have a wonderful day!
> >
> > Best regards,
> > Yee Hui
> --
> The NEC-List mailing list <nec-list_at_gweep.ca>
> http://www.gweep.ca/mailman/listinfo.cgi/nec-list

-- 
-----------------------------
The Numeric Python EM Project
www.pythonemproject.com
-- 
The NEC-List mailing list <nec-list_at_gweep.ca>
http://www.gweep.ca/mailman/listinfo.cgi/nec-list
Received on Wed Nov 27 2002 - 14:43:13 EST