General Helix Modeling Question:
I have modeled a simple helix,
CM
CM HELIX with infinite ground plane
CM Runs with Nittnay Scientific GNEC ver 1.1.
CM All values are in meters
CE
GH 1 120 19 0.4156 0.01638 0.01638 0.001 0.001 0
GM 0 0 0 0 0 0 0 0.006 0
GW 22 3 0.01638 0.0 0.000 0.01638 0.0 0.006 0.001
GE 1 0 0
GN 1
FR 0 5 0 0 2100 50
EX 0 22 2 00 1.0 0.0
RP 0 91 1 1000 -90 0 2.00000 1.00000
EN
The total gain vs. frequency is
2100 16.48
2150 15.46
2200 14.9
2250 14.5
2300 14.4
Seems nice except that the experimentally determined gains are increasing
with frequency rather than decreasing (infact, almost like the numbers are
reversed, the lowest gain is about 14.4 at 2100 and the highest is about
16.5 at 2300). Comments?
Cheers,
Bruce Blevins
-- The NEC-List mailing list NEC-List_at_robomod.net http://www.robomod.net/mailman/listinfo/nec-listReceived on Wed Feb 03 2010 - 18:14:26 EST