Re: NEC-LIST: PT command

From: Jim Lux <James.P.Lux_at_email.domain.hidden>
Date: Thu, 07 Apr 2005 16:47:28 -0500

At 02:35 PM 4/7/2005, D. B. Miron wrote:
>Good day,
>
>How do I get the current in just two different segments
>without printing all the currents? I tried to PT commands
>in a row, but only the first executed. Thanks.
>
>Regards,
>Doug Miron
>
I don't think you can, easily.

One trick, though, is to put a EX in the desired segment, with a very low
voltage (1E-10 volts). Then, the current in that feedpoint (which is the
same as the current in the segment) will be printed in the list of
excitations. You'd ignore the impedance and admittance, of course.

I've used this to calculate mutual admittance matrices.