The attached listing which describes a half-wave dipole with some
supporting structure generates negative resistance. Do we have a
solution to the energy crisis?
Any comments or explanations are most welcome.
CM sailing1 dipol balun Z0=136 ohm and support
CE
GW 1 19 0.0 0.0 0.0375 0.0 0.0 -0.0375 0.00175
GW 2 10 0.0 0.0 0.003 0.0 -0.03 0.003 0.00175
GW 3 10 0.0 0.0 -0.003 0.0 -0.03 -0.003 0.00175
GW 4 5 0.0 -0.03 0.03 0.0 -0.03 -0.03 0.00175
GE 0
FR 0 1 0 0 2000 10.0000 0.00E+00
EX 0 1 10 0 1.00E+00 0.00E+00
RP 0 1 360 1001 90.00E+00 0.00E+00 0.00E+00 1.00E+00
EN
take care,
Peter.