Hi,

I am using the pc version nec2. while simulating for larger number of
segments, I switch to the UNIX NEC. However, with the same input card
that I have created for the PC-NEC, the unix NEC always claim that the
input geometry has error. I wonder can anyone help me on this??
Thanks in advance.

Below is my input cards for PC-NEC (since the number of segments used
is small). The attached nov1a.out file is the output file from the
unix nec

---------------------
CE
GW,41,1,0,0,-0.007495,0,0,0.007495,0.001
GW,41,2,0,-0.0008994,-0.0112425,0,-0.0008994,-0.007495,0.001
GW,41,3,0,-0.0008994,-0.007495,0,-0.007495,-0.007495,0.001
GW,41,4,0,-0.007495,-0.007495,0,-0.007495,0.007495,0.001
GW,41,5,0,-0.007495,0.007495,0,-0.0008994,0.007495,0.001
GW,41,6,0,-0.0008994,0.007495,0,-0.0008994,0.0112425,0.001
GW,41,7,0,0.0037475,-0.007495,0,0.0037475,0.007495,0.001
GE
FR,0,1,0,0,10000.,0
EX,0,0,21,0,1.,0.
RP,0,361,1,0,0,90,1,0,0,0
EN
-----------------------

With the above input cards, this is what the unix nec returns...

-----------------------
 Start Time: Fri Dec 5 14:41:58 1997
 GEOMETRY DATA CARD ERROR
-----------------------

Thanks again.

Boon Phing
_________________________________________________________
DO YOU YAHOO!?
Get your free @yahoo.com address at http://mail.yahoo.com

 Input file name: nov1a.nec
 Output file name:nov1a.out
 Start Time: Fri Dec 5 14:41:58 1997
1

                                 ************************************

                                    NUMERICAL ELECTROMAGNETICS CODE

                                 ************************************

                                     - - - - COMMENTS - - - -

                                 - - - STRUCTURE SPECIFICATION - - -

                                     COORDINATES MUST BE INPUT IN
                                     METERS OR BE SCALED TO METERS
                                     BEFORE STRUCTURE INPUT IS ENDED

  WIRE
  NO. X1 Y1 Z1 X2 Y2 Z2
     1 0.00001 0.00000 0.00000 -0.00749 0.00000 0.00000
     2 0.00002 0.00000 -0.00090 NaN -0.01124 NaN

             NO. OF FIRST LAST TAG
   RADIUS SEG. SEG. SEG. NO.
   0.00750 41 1 41 0
   0.00000 41 42 82 0

-------------------------------------------------------------------------------
Received on Wed Dec 10 1997 - 09:39:49 EST